RHH Kab Pou Chanm Envèstisè Enèji Renouvlab ak Switchgear

RHH Kab Pou Chanm Envèstisè Enèji Renouvlab ak Switchgear
Details:
·Kondiktè: Soild fè kòb kwiv mete pa ASTM B3, Klas B konprese kòb kwiv mete pa ASTM B3 ak B8, oswa 19-strand konbinezon unilay kwiv pa ASTM B3 ak B787
·Izolasyon: Cross Linked Polyethylene (XLPE) Kalite RHH/RHW-2 oswa USE-2, Segondè Chalè, Imidite ak Abrasion Rezistan
·Vòltaj: 600V/1000V/2000V
Send Inquiry
Download
Deskripsyon
Paramèt teknik
Sètifikasyon

Dongguan Greater Wire & Cable co, Ltd se youn nan dirijan manifaktirè yo ak founisè nan kab rhh pou chanm varyateur enèji renouvlab ak switchgear nan Lachin, tou sipòte sèvis Customized. Tanpri asire w ke an gwo dirab rhh kab pou chanm varyateur enèji renouvlab ak switchgear te fè nan peyi Lachin isit la soti nan faktori nou an. Si ou gen nenpòt ankèt sou echantiyon gratis, tanpri ou lib pou imèl nou.

 

UL44 copper building RHH wire

PWODWI REAL SHOT

 

UL44 copper building RHH cable
UL44 copper conductor RHH wire
UL44 copper conductor RHH cable

UL44 single conductor RHH wire

Fil elektrik Thermoset Copper pou Pwoteje Van Solè ak Enstalasyon Distribisyon pouvwa Microgrid
RHH Kab pou enèji renouvlabka aplike nan distribisyon pouvwa bilding ki pwoteje-nan solè, van ak enstalasyon mikwo-gri kote konsepsyon elektrik la mande pou fil elektrik UL44 RHH. GERITEL WIRE bay kondiktè kwiv bloke ak izolasyon thermoset pou sèvis 90 degre sèk -kote nan chanm varyateur, zòn switchgear ak espas ekipman elektrik. Fil chanm RHH varyateur pa ta dwe konfonn ak fil PV dedye yo itilize sou sikwi modil, men li ka sèvi fonksyon distribisyon fiks ki apwopriye nan etablisman an. GERITEL WIRE bay kab pouvwa enèji renouvlab ak idantifikasyon pwojè, opsyon longè bobine -, personnalisation anbalaj ak planifikasyon livrezon an gwo pou kliyan EPC ak OEM.
PWODWI SPECIFICATIONS

 

RHH cable for raceway power wiring

Aplikasyon ak Deskripsyon

 

Itilizasyon GERITEL WIRE -2 600 Volts oswa RHH/RHW-2 1000 Volts kab pouvwa yo apwopriye pou itilize nan zòn mouye ak sèk, konduit, kanal, depresyon, antèman dirèk, ayeryen ki sipòte pa yon mesaje, ak kote pwopriyete elektrik siperyè yo vle. Kab sa yo kapab opere kontinyèlman nan tanperati kondiktè a pa depase 90 degre pou operasyon nòmal nan kote mouye ak sèk, 130 degre pou surcharge ijans, ak 250 degre pou kondisyon sikwi kout. Rated pou 1000 lb/ft maksimòm presyon flan.

SPECIFICATIONS
·ASTM B3 Fil kwiv mou oswa rkwit
·ASTM B8 Konsantrik-Lay-kondiktè kòb kwiv mete
·ASTM B787 19 Konbinezon fil Unilay-Bonn kondiktè kwiv
·UL 44 Thermoset-Izole Fil ak Câbles
· UL 854 Sèvis Antre Kab
· ICEA S-95-658 (NEMA WC70) Câbles pouvwa ki te evalye 2000 Volts oswa mwens pou distribisyon enèji elektrik
·RoHS-2 (Direktif Ewopeyen an 2011/65/EU)

Tablo 1 - Pwa ak Mezi

Kond. Gwosè Konte Strand Dyamèt sou kondiktè Ensul. Epesè Koulè izolasyon Apeprè. OD Pwa Copper Apeprè. Pwa

AWG/Kcmil

Nimewo nan Strands pous mil pous lb/1000ft lb/1000ft
14 7 0.070

45

BK 0.161 12 20
12 Solid 0.080 45 BK 0.174 19 28
12 7 0.088 45 BK 0.179 20 28
10 7 0.113 45 BK 0.203 32 42
8 7 0.141 60 BK 0.259 95 67
6 7 0.177 60 BN 0.300 81 102
4 7 0.225 60 BK 0.345 128 153
3 7 0.252 60 BK 0.378 162 191
2 7 0.282 60 NOU 0.403 205 244
1 19 0.322 80 BK 0.481 258 304
1/0 19 0.361 80 BK 0.522 325 390
2/0 19 0.405 80 GN 0.564 410 481
3/0 19 0.456 80 BK 0.616 518 598
4/0 19 0.512 80 GN 0.672 653 742
250 37 0.558 95 BK 0.748 771 884
300 37 0.610 95 BK 0.801 926 1023
350 37 0.661 95 BK 0.851 1081 1213
400 37 0.705 95 BK 0.896 1235 1345
500 37 0.789 95 BN 0.956 1544 1696
600 61 0.865 110 YW 1.085 1853 2028
750 61 0.968 110 GN 1.171 2315 2492
1000 61 1.117 110 BK 1.337 3088 3283
Tout dimansyon yo nominal ak sijè a tolerans fabrikasyon nòmal
◊ Kab ki make ak senbòl sa a se yon atik estanda
• Kòd stock TBA yo se estimasyon sèlman ak pwodwi aktyèl la ka varye. Tanpri tann jiskaske yo bay yon kòd stock pou achte konektè ak/oswa ekipman.

Tablo 2 - Done Elektrik ak Jeni

Kond. Gwosè Min koube
Reyon
Max Rale
Tansyon
DC Rezistans @
25 degre
AC Rezistans @
75 degre
Reyaksyon endiktif
@60Hz
Anpasite admisib
Nan 75 degre
Anpasite admisib
Nan 90 degre

AWG/Kcmil

pous lb Ω/1000ft Ω/1000ft Ω/1000ft Amp Amp
14 0.6 32 2.631 3.170 0.058 20 25
12 0.7 52 1.662 2.002 0.054 25 30
12 0.7 52 1.662 2.002 0.054 25 30
10 0.8 83 1.040 1.253

0.050

35 40
8 1.0 132 0.653 0.786 0.052 50 55
6 1.2 209 0.411 0.495 0.051 65 75
4 1.4 333 0.258 0.310 0.048 85 95
3 1.5 420 0.205 0.246 0.047 100 115
2 1.6 530 0.162 0.195 0.046 115 130
1 1.9 669 0.128 0.154 0.045 130 145
1/0 2.1 844 0.102 0.122 0.044 150 170
2/0 2.3 1064 0.081 0.097 0.043 175 195
3/0 2.5 1342 0.064 0.078 0.042 200 225
4/0 2.7 1692 0.051 0.062 0.041 230 260
250 3.0 2000 0.043 0.053 0.041 255 290
300 3.2 2400 0.036 0.045 0.041 285 320
350 3.4 2800 0.031 0.039 0.040 310 350
400 3.6 3200 0.027 0.035 0.040 335 380
500 3.8 4000 0.022 0.029 0.039 380 430
600 5.4 4800 0.018 0.025 0.039 420 475
750 5.9 6000 0.014 0.022 0.038 475 535
1000 6.7 8000 0.011 0.018 0.037 545 615
• Anpasite ki baze sou 2023 NEC Tablo 310.16 epi yo pa pran an konsiderasyon limit pwoteksyon surkouran nan NEC 240.4(D) nan 15 Amp pou 14 AWG CU, 20.
Ampè pou 12 AWG CU, ak 30 Amp pou 10 AWG CU (endepandan de evalyasyon tanperati kondiktè a ak bloke si gwosè a prezan nan tablo). Epitou, gade seksyon NEC yo
310.15 ak 110.14(C) pou kondisyon adisyonèl.
• Reaktans endiktif baze sou konduit ki pa-fèr ak yon sant espas dyamèt-a-sant.
SÈTIFIKASYON

 

UL44 single conductor RHH cable

Anbalaj

 

UL44 XLPE insulated RHH wire

Woule

UL44 XLPE insulated RHH cable

Ti bobine an bwa

UL44 cross linked polyethylene insulated RHH wire

Gwo bobine an bwa

APLIKASYON

 

UL44 single core RHH wire
Enstalasyon konduit anba tè
UL44 cross linked polyethylene insulated RHH cable
Fil elektrik kondit
UL44 90C dry location RHH wire
Câblage Awondisman Feeder
KA

 

UL44 90C dry location RHH cable

Tesla Gigafactory Texas

UL44 dry location certified RHH wire

Inivèsite Stanford Kalifòni Etazini

UL44 dry location certified RHH cableA

Mayo Clinic Hospital, Saint Marys Campus

POUKISA CHWAZI NOU

 

30Ane eksperyans
nan yon sèl-sèvis

Dongguan Greater Wire & Cable Co., Ltd. se yon manifakti kab pwofesyonèl jeni -nan Lachin, ki bay solisyon kab elektrik sètifye pou pwojè bilding, endistriyèl, min, enèji ak enfrastrikti atravè lemond.

Avèk yon faktori 30,000 m², 30 liy pwodiksyon, enjenyè ki gen eksperyans, ak yon ekip kontwòl kalite strik, nou bay pwodwi kab serye, trasabl, ak konfòme pou aplikasyon jeni entènasyonal yo. Pwodwi nou yo sipòte pa sètifikasyon ki gen ladan SAA, UL, cUL, VDE, TÜV, CE, CB, IEC, BPS, ak ISO.

Nou pran angajman pou sekirite, kalite, transparans, ak patenarya alontèm-. Soti nan enspeksyon matyè premyè rive nan tès pwodwi fini, chak pakèt yo ak anpil atansyon kontwole pou asire pèfòmans ki estab ak itilizasyon serye nan pwojè.

Pi gwo kab - Kalite sètifye. Pwovizyon pou serye. Valè Jeni.

UL44 high heat RHH wire
 
15K
Pwojè fini
150+
anplwaye pwofesyonèl
15K
kliyan kontan
92+
prim ak sètifika
EKIPMAN PLANT

 

UL44 high heat RHH cable
 
UL44 building RHH cable
 
UL44 power RHH wire
 
UL44 power RHH cable
 
UL44 industrial RHH wire
 
UL44 industrial RHH cable
 
SÈTIFIKASYON GLOBAL

 

UL44 electrical RHH wire

FOTO KLIYAN
 

UL44 electrical RHH cable

TRANSPÒ ENTERNASYONAL

 

01

Kago lanmè

Nou ofri solisyon machandiz fyab pou gwo -lòd volim. Machandiz ou yo byen chaje ak anbake nan resipyan, sa ki garanti pri -livrezon efikas nan pò atravè lemond.

02

Kago Air

Pou livrezon pi rapid, sèvis machandiz lè nou an asire pwodwi ou yo rive nan destinasyon entènasyonal yo byen vit, ak manyen atansyon ak swiv konplè sou wout la.

03

Entènasyonal Express

Bezwen anbakman ijan? Sèvis entènasyonal eksprime nou an delivre ti kòmand mwayen avèk efikasite, bay sèvis pòt-a-pòt ak tan reyèl-swiv pou lapè lespri.

ASTM B3 copper conductor RHH wire
PATÈ Koperativ

 

Nou ap chèche yon patnè koperativ pou elaji biznis nou an.

ASTM B3 copper conductor RHH cable
ASTM B8 stranded copper conductor RHH wire
ASTM B8 stranded copper conductor RHH cable
ASTM B3 B8 copper conductor RHH wire
ASTM B3 B8 copper conductor RHH cable
NEC building RHH wire
NEC building RHH cable
NEC raceway RHH wire
NEC raceway RHH cable
NEC conduit RHH wire
Kijan Pou Kowopere Ak Nou?

Senpleman pataje kondisyon ou yo, resevwa solisyon pwofesyonèl nou an, konfime echantiyon yo epi jwi pwodiksyon rapid, serye ak livrezon atravè lemond - travay avèk nou se sa ki fasil.

Adrès nou an

Bilding 2, No. 40 Luxi 2nd Road, Liaobu Town, Dongguan City, Guangdong Province, Lachin

Nimewo Telefòn

+86 136 6257 9592

+86 135 1078 4550

E-lapòs

manager01@greaterwire.com

NEC conduit RHH cable
FAQ

 

Èske koulè izolasyon an ka Customized?
Koulè ki disponib yo ka revize pandan konfimasyon lòd. GERITEL WIRE sipòte fil koulè koutim RHH pou pwojè ki bezwen idantifikasyon sikwi pi klè, jesyon faz oswa diferansyasyon OEM, bay koulè yo mande a konpatib ak spesifikasyon pwodiksyon apwouve a.
Èske mwen ka mande enprime koutim sou kab RHH?
Wi. Lejand sifas yo ka configuré pou idantifikasyon pwodwi apwouve, mak kliyan oswa referans pwojè nan kondisyon maketing.koutim enprime RHH kabse itil pou distribitè, kontraktè ak OEM ki vle pi fasil trasabilite atravè livrezon gwo.
Èske GERITEL WIRE ka bay longè bobin koutim?
Wi. Longè bobin oswa pake ka planifye alantou pwodiksyon ak kondisyon pwojè. Longè koutim RHH fil ka diminye fatra, senplifye etap materyèl ak fè li pi fasil pou kontraktè oswa manifaktirè modilè bay materyèl nan zòn travay espesifik.
Èske anbalaj fil RHH ka Customized?
GERITEL WIRE ka revize kalite bobin, etikèt, palètizasyon ak lòt bezwen anbalaj pou lòd esansyèl. kab RHH ki pakè koutim ede distribitè ak achtè pwojè amelyore manyen depo, planifikasyon veso ak idantifikasyon materyèl travay-sit.

 

Hot Tags: rhh kab pou chanm varyateur enèji renouvlab ak switchgear, Lachin rhh kab pou chanm varyateur enèji renouvlab ak switchgear manifaktirè, Swèd, faktori

Send Inquiry