XLP RHH fil UL44 Copper Building Kab pou kote sèk

XLP RHH fil UL44 Copper Building Kab pou kote sèk
Details:
·Kondiktè: Soild fè kòb kwiv mete pa ASTM B3, Klas B konprese kòb kwiv mete pa ASTM B3 ak B8, oswa 19-strand konbinezon unilay kwiv pa ASTM B3 ak B787
·Izolasyon: Cross Linked Polyethylene (XLPE) Kalite RHH/RHW-2 oswa USE-2, Segondè Chalè, Imidite ak Abrasion Rezistan
·Vòltaj: 600V/1000V/2000V
Send Inquiry
Download
Deskripsyon
Paramèt teknik
Sètifikasyon

Dongguan Greater Wire & Cable co, Ltd se youn nan dirijan manifaktirè yo ak founisè nan xlp rhh fil ul44 kwiv bilding kab pou kote sèk nan Lachin, tou sipòte sèvis Customized. Tanpri, asire w ke an gwo dirab xlp rhh fil ul44 kwiv bilding kab pou kote sèk te fè nan peyi Lachin isit la soti nan faktori nou an. Si ou gen nenpòt ankèt sou echantiyon gratis, tanpri ou lib pou imèl nou.

 

RHH wire for rail transit electrical rooms

PWODWI REAL SHOT

 

RHH cable for rail transit electrical rooms
RHH wire for metro station power distribution
RHH cable for metro station power distribution

RHH wire for train station electrical systems

Cross Linked Thermoset izolasyon pou 90 degre bilding ak sistèm elektrik endistriyèl
XLP RHH Filse lajman ki itilize pou dekri konstriksyon RHH ak izolasyon tèrmoset ki lye kwa-. GERITEL WIRE fabrike UL44 kab bilding kwiv ak kondiktè kwiv bloke ak izolasyon Enjenieri pou sèvis 90 degre nan kote sèk. Kab la ka sipòte fil elektrik fiks nan sistèm pouvwa bilding, chanm elektrik endistriyèl, kanal ak enstalasyon kous kote spesifikasyon pwojè a mande pou RHH. Fil kote sèk RHH sa a disponib ak plizyè opsyon vòltaj ak idantifikasyon personnalisable, koulè, longè bobin ak anbalaj. Faktori-pwodiksyon dirèk ede distribitè yo ak kontraktè yo kenbe bon jan kalite konsistan nan tout lòd pwojè repete.
PWODWI SPECIFICATIONS

 

RHH cable for train station electrical systems

Aplikasyon ak Deskripsyon

 

Itilizasyon GERITEL WIRE -2 600 Volts oswa RHH/RHW-2 1000 Volts kab pouvwa yo apwopriye pou itilize nan zòn mouye ak sèk, konduit, kanal, depresyon, antèman dirèk, ayeryen ki sipòte pa yon mesaje, ak kote pwopriyete elektrik siperyè yo vle. Kab sa yo kapab opere kontinyèlman nan tanperati kondiktè a pa depase 90 degre pou operasyon nòmal nan kote mouye ak sèk, 130 degre pou surcharge ijans, ak 250 degre pou kondisyon sikwi kout. Rated pou 1000 lb/ft maksimòm presyon flan.

SPECIFICATIONS
·ASTM B3 Fil kwiv mou oswa rkwit
·ASTM B8 Konsantrik-Lay-kondiktè kòb kwiv mete
·ASTM B787 19 Konbinezon fil Unilay-Bonn kondiktè kwiv
·UL 44 Thermoset-Izole Fil ak Câbles
· UL 854 Sèvis Antre Kab
· ICEA S-95-658 (NEMA WC70) Câbles pouvwa ki te evalye 2000 Volts oswa mwens pou distribisyon enèji elektrik
·RoHS-2 (Direktif Ewopeyen an 2011/65/EU)

Tablo 1 - Pwa ak Mezi

Kond. Gwosè Konte Strand Dyamèt sou kondiktè Ensul. Epesè Koulè izolasyon Apeprè. OD Pwa Copper Apeprè. Pwa

AWG/Kcmil

Nimewo nan Strands pous mil pous lb/1000ft lb/1000ft
14 7 0.070

45

BK 0.161 12 20
12 Solid 0.080 45 BK 0.174 19 28
12 7 0.088 45 BK 0.179 20 28
10 7 0.113 45 BK 0.203 32 42
8 7 0.141 60 BK 0.259 95 67
6 7 0.177 60 BN 0.300 81 102
4 7 0.225 60 BK 0.345 128 153
3 7 0.252 60 BK 0.378 162 191
2 7 0.282 60 NOU 0.403 205 244
1 19 0.322 80 BK 0.481 258 304
1/0 19 0.361 80 BK 0.522 325 390
2/0 19 0.405 80 GN 0.564 410 481
3/0 19 0.456 80 BK 0.616 518 598
4/0 19 0.512 80 GN 0.672 653 742
250 37 0.558 95 BK 0.748 771 884
300 37 0.610 95 BK 0.801 926 1023
350 37 0.661 95 BK 0.851 1081 1213
400 37 0.705 95 BK 0.896 1235 1345
500 37 0.789 95 BN 0.956 1544 1696
600 61 0.865 110 YW 1.085 1853 2028
750 61 0.968 110 GN 1.171 2315 2492
1000 61 1.117 110 BK 1.337 3088 3283
Tout dimansyon yo nominal ak sijè a tolerans fabrikasyon nòmal
◊ Kab ki make ak senbòl sa a se yon atik estanda
• Kòd stock TBA yo se estimasyon sèlman ak pwodwi aktyèl la ka varye. Tanpri tann jiskaske yo bay yon kòd stock pou achte konektè ak/oswa ekipman.

Tablo 2 - Done Elektrik ak Jeni

Kond. Gwosè Min koube
Reyon
Max Rale
Tansyon
DC Rezistans @
25 degre
AC Rezistans @
75 degre
Reyaksyon endiktif
@60Hz
Anpasite admisib
Nan 75 degre
Anpasite admisib
Nan 90 degre

AWG/Kcmil

pous lb Ω/1000ft Ω/1000ft Ω/1000ft Amp Amp
14 0.6 32 2.631 3.170 0.058 20 25
12 0.7 52 1.662 2.002 0.054 25 30
12 0.7 52 1.662 2.002 0.054 25 30
10 0.8 83 1.040 1.253

0.050

35 40
8 1.0 132 0.653 0.786 0.052 50 55
6 1.2 209 0.411 0.495 0.051 65 75
4 1.4 333 0.258 0.310 0.048 85 95
3 1.5 420 0.205 0.246 0.047 100 115
2 1.6 530 0.162 0.195 0.046 115 130
1 1.9 669 0.128 0.154 0.045 130 145
1/0 2.1 844 0.102 0.122 0.044 150 170
2/0 2.3 1064 0.081 0.097 0.043 175 195
3/0 2.5 1342 0.064 0.078 0.042 200 225
4/0 2.7 1692 0.051 0.062 0.041 230 260
250 3.0 2000 0.043 0.053 0.041 255 290
300 3.2 2400 0.036 0.045 0.041 285 320
350 3.4 2800 0.031 0.039 0.040 310 350
400 3.6 3200 0.027 0.035 0.040 335 380
500 3.8 4000 0.022 0.029 0.039 380 430
600 5.4 4800 0.018 0.025 0.039 420 475
750 5.9 6000 0.014 0.022 0.038 475 535
1000 6.7 8000 0.011 0.018 0.037 545 615
• Anpasite ki baze sou 2023 NEC Tablo 310.16 epi yo pa pran an konsiderasyon limit pwoteksyon surkouran nan NEC 240.4(D) nan 15 Amp pou 14 AWG CU, 20.
Ampè pou 12 AWG CU, ak 30 Amp pou 10 AWG CU (endepandan de evalyasyon tanperati kondiktè a ak bloke si gwosè a prezan nan tablo). Epitou, gade seksyon NEC yo
310.15 ak 110.14(C) pou kondisyon adisyonèl.
• Reaktans endiktif baze sou konduit ki pa-fèr ak yon sant espas dyamèt-a-sant.
SÈTIFIKASYON

 

RHH wire for transportation infrastructure

Anbalaj

 

RHH cable for transportation infrastructure

Woule

RHH wire for government building electrical systems

Ti bobine an bwa

RHH cable for government building electrical systems

Gwo bobine an bwa

APLIKASYON

 

RHH cable for municipal building power distribution
Enstalasyon konduit anba tè
RHH wire for commercial high rise buildings
Fil elektrik kondit
RHH cable for commercial high rise buildings
Câblage Awondisman Feeder
KA

 

RHH wire for industrial facilities

Tesla Gigafactory Texas

RHH cable for industrial facilities

Inivèsite Stanford Kalifòni Etazini

RHH wire for manufacturing plants

Mayo Clinic Hospital, Saint Marys Campus

POUKISA CHWAZI NOU

 

30Ane eksperyans
nan yon sèl-sèvis

Dongguan Greater Wire & Cable Co., Ltd. se yon manifakti kab pwofesyonèl jeni -nan Lachin, ki bay solisyon kab elektrik sètifye pou pwojè bilding, endistriyèl, min, enèji ak enfrastrikti atravè lemond.

Avèk yon faktori 30,000 m², 30 liy pwodiksyon, enjenyè ki gen eksperyans, ak yon ekip kontwòl kalite strik, nou bay pwodwi kab serye, trasabl, ak konfòme pou aplikasyon jeni entènasyonal yo. Pwodwi nou yo sipòte pa sètifikasyon ki gen ladan SAA, UL, cUL, VDE, TÜV, CE, CB, IEC, BPS, ak ISO.

Nou pran angajman pou sekirite, kalite, transparans, ak patenarya alontèm-. Soti nan enspeksyon matyè premyè rive nan tès pwodwi fini, chak pakèt yo ak anpil atansyon kontwole pou asire pèfòmans ki estab ak itilizasyon serye nan pwojè.

Pi gwo kab - Kalite sètifye. Pwovizyon pou serye. Valè Jeni.

RHH cable for manufacturing plants
 
15K
Pwojè fini
150+
anplwaye pwofesyonèl
15K
kliyan kontan
92+
prim ak sètifika
EKIPMAN PLANT

 

RHH wire for assembly plants
 
RHH cable for assembly plants
 
RHH wire for automotive manufacturing facilities
 
RHH cable for automotive manufacturing facilities
 
RHH wire for electronics manufacturing plants
 
RHH cable for electronics manufacturing plants
 
SÈTIFIKASYON GLOBAL

 

RHH wire for semiconductor manufacturing facilities

FOTO KLIYAN
 

RHH cable for semiconductor manufacturing facilities

TRANSPÒ ENTERNASYONAL

 

01

Kago lanmè

Nou ofri solisyon machandiz fyab pou gwo -lòd volim. Machandiz ou yo byen chaje ak anbake nan resipyan, sa ki garanti pri -livrezon efikas nan pò atravè lemond.

02

Kago Air

Pou livrezon pi rapid, sèvis machandiz lè nou an asire pwodwi ou yo rive nan destinasyon entènasyonal yo byen vit, ak manyen atansyon ak swiv konplè sou wout la.

03

Entènasyonal Express

Bezwen anbakman ijan? Sèvis entènasyonal eksprime nou an delivre ti kòmand mwayen avèk efikasite, bay sèvis pòt-a-pòt ak tan reyèl-swiv pou lapè lespri.

RHH wire for microchip plants
PATÈ Koperativ

 

Nou ap chèche yon patnè koperativ pou elaji biznis nou an.

RHH cable for microchip plantsa
RHH wire for food processing plants
RHH cable for food processing plants
RHH wire for pharmaceutical manufacturing plants
RHH cable for pharmaceutical manufacturing plants
RHH wire for chemical plant electrical rooms
RHH cable for chemical plant electrical rooms
RHH wire for oil and gas facility electrical rooms
RHH cable for oil and gas facility electrical rooms
RHH wire for refinery electrical rooms
Kijan Pou Kowopere Ak Nou?

Senpleman pataje kondisyon ou yo, resevwa solisyon pwofesyonèl nou an, konfime echantiyon, epi jwi pwodiksyon rapid, serye ak livrezon atravè lemond - travay avèk nou se sa ki fasil.

Adrès nou an

Bilding 2, No. 40 Luxi 2nd Road, Liaobu Town, Dongguan City, Guangdong Province, Lachin

Nimewo Telefòn

+86 136 6257 9592

+86 135 1078 4550

E-lapòs

manager01@greaterwire.com

RHH cable for refinery electrical rooms
FAQ

 

Èske fil RHH apwopriye pou pwojè antretyen endistriyèl?
RHH ka apwopriye pou pwojè antretyen endistriyèl lè kondiktè yo enstale nan kote ki pwoteje sèk epi pwojè a mande pou fil elektrik izole UL44 thermoset -. GERITEL WIRE founi fil ranplasman RHH ak kondiktè kwiv bloke, pèfòmans sèk -90 degre ak opsyon B2B pou longè pwojè, etikèt ak anbalaj esansyèl.
Èske yo ka itilize fil RHH andedan kabinè distribisyon pouvwa?
RHH ka itilize pou chemen pouvwa fiks apwopriye ki asosye ak kabinè distribisyon pouvwa lè konsepsyon ekipman an espesifye kondiktè UL44 ak anviwònman fil elektrik la pwoteje epi sèk. GERITEL WIRE founitiRHH fil pou kabinè pouvwaak konstriksyon an kwiv bloke ak idantifikasyon Customized pou bòs mason panèl OEM.
Èske kab RHH apwopriye pou koneksyon switchgear?
Wi, RHH ka itilize pou koneksyon fiks pwoteje alantou switchgear lè gwosè kondiktè, vòltaj ak kondisyon chemen yo satisfè. GERITEL WIRE founi RHH switchgear kab pou chanm elektrik ak sistèm distribisyon endistriyèl, ak pwojè -longè bobin ak mak.
Èske yo ka itilize fil RHH nan kabinè kontwòl?
RHH ka sipòte fil elektrik nan kabinè kontwòl ak ekipman ki gen rapò lè konsepsyon an mande pou yon kondiktè kwiv thermoset -izole. Fil kabinè kontwòl RHH ki soti nan GERITEL WIRE fèt pou sikui fiks -kote sèk olye ke gwo-mouvman machin flex.

 

Hot Tags: xlp rhh fil ul44 kòb kwiv mete bilding kab pou kote sèk, Lachin xlp rhh fil ul44 kòb kwiv mete kab bilding pou kote sèk manifaktirè, Swèd, faktori

Send Inquiry