4/0 AWG UL1277 TC-ER Kab plato ak THHN THWN-2 kondiktè

4/0 AWG UL1277 TC-ER Kab plato ak THHN THWN-2 kondiktè
Details:
·PVC an jeneral jakèt
·Stranded Bare Copper Ground Conductor
· Ripcord (jan sa nesesè)
·PVC D' kouvri ak nayilonn
·Blanke Bare Copper Kondiktè
· Filler (jan sa nesesè)
· Evalyasyon vòltaj: 600V
· Tanperati: Evalyasyon nan 90 degre mouye oswa sèk
· Ranje gwosè: 12AWG ~ 750kcmil
· Estanda: UL83/UL1277
·3 oswa 4 kondiktè
· Koulè: nwa
Send Inquiry
Download
Deskripsyon
Paramèt teknik
Sètifikasyon

Nylon Jacket Cable

PWODWI REAL SHOT

 

UL Approved TC-ER Cable
UL Industrial Cable Standard
Industrial Cable

Industrial Tray Cable

4/0 AWG TC-ER - Maksimòm Anpasite pou gwo Endistriyèl Power Feeders
Lè gwo motè, ponp lou, oswa panno distribisyon prensipal mande livrezon maksimòm pouvwa,4/0 AWG TC-ER kab platobay anpasite ki nesesè. Kab sa a ki bloke kondiktè kwiv pi bon kalite akPVC + Nylon doub -izolasyon kouchak yon jakèt PVC dirab, ki bay pèfòmans serye nan plant endistriyèl ak estasyon. UL1277 ak UL83 sètifye ak yon evalyasyon 600V, li sipòte enstalasyon kouri ekspoze nan plato kab san kanal. Izolasyon PVC + Nylon ofri rezistans siperyè nan imidite, lwil oliv, ak fwotman, asire fyab alontèm -nananviwònman endistriyèl difisil. Jakèt PVC rezistan a bay pwoteksyon mekanik ak rezistans limyè solèy la pou aplikasyon andedan kay la ak deyò.
PWODWI SPECIFICATIONS

 

THHN Tray Cable

Deskripsyon Product

 

PVC/Nylon/PVC (THHN/THWN-2), 600V Power, TC-ER Direct Antèman Kab konpoze de kondiktè ki kouvri nèt ak kwiv klas B ki kouvri, ki kouvri ak klori Polyvinyl (PVC) ak lwil oliv ak gaz rezistan izolasyon Nylon, unshielded ak nwa PVC jakèt. Câbles sa yo te itilize nan pouvwa endistriyèl.

Aplikasyon

 
  • Nan kanal, kanal, lè gratis, kous ak antèman dirèk, enstalasyon prensipal yo enkli plato kab, ak kote deyò.
  • Nan kote ki mouye oswa sèk
  • Apwouve pou Klas I, Div. 2 kote ki gen danje ladan pou chak NEC
  • Pèmèt pou itilize Exposed Run (ER) an akò ak NEC pou 3 oswa plis kondiktè

Karakteristik

 
  • Evalyasyon nan 90 degre mouye oswa sèk
  • Ripcord (jan sa nesesè)
  • Ekselan rezistans limyè solèy la
  • Satisfè tès koube frèt nan -25 degre
SPECIFICATIONS

Konte kondiktè

Disponib nan 3 oswa 4 kondiktè

Kondiktè

Konplètman rkwit fè kòb kwiv mete Klas B konprese strand pa ASTM B8

Gwosè kalib

Disponib nan 12 AWG jiska 750 kcmil

Izolasyon

Klori Polyvinyl (PVC) kouvri ak

  • Tout mezi yo se kalite THHN/THWN-2
Koulè kodaj Dapre ICEA S-58-679 Metòd 4 oswa Metòd 1, Tablo E-1 (K-1) oswa E-2 (K-2); opsyon adisyonèl kodaj koulè ki disponib
Ranpli File ki pa-igroskopik, jan sa nesesè pou jwenn yon seksyon transvèsal sikilè
Kondiktè tè Tè kòb kwiv mete san izole
Si ou vle: tè izole
Jacket Klori polivinil (PVC)

Marking jakèt

00000 FT GREATER FIL XXXAWG XX/C THHN/THWN-2 PVC JKT 600V 90C TIP MOYE OSWA SEK TC-ER (UL) SUN RES DIR ANTERMAN FE NAN CHINA MMDDYYYY

Anbalaj

Bobine bwa ki pa ka retounen -nan yon varyete longè ak dimansyon

Konfòmite pèfòmans

ASTM B3, ASTM B8
UL 83
UL1277
UL 1685 (tès ekspoze flanm dife)
ANSI/NEMA WC 70/ICEA S-95-658
FT4/IEEE1202 (konfòmite flanm dife)
NEC

Lòt Konfòmite

EPA 40 CFR, Pati 261
OSHA
RoHS-konfòme/RoHS 2-konfòme
REACH-konfòme

TC-ER Plato Kab ak THHN/THWN-2Fèy done Copper Conductors

Konte kondiktè Gwosè kondiktè AWG/kcmil Gwosè tè AWG Epesè izolasyon
nan (mm)
Epesè jakèt
nan (mm)
Apeprè. An jeneral dyamèt
nan (mm)
Apeprè. Pwa nèt
lbs/kft (kg/km)

3

12 12 0.020(0.51) 0.045(1.14) 0.39(9.9) 135(195)
4 12 12 0.020(0.51) 0.045(1.14) 0.43(10.8) 160 (237)
3 10 10 0.025(0.64) 0.045(1.14) 0.46(11.8) 200(291)
4 10 10 0.025(0.64) 0.045(1.14) 0.51(12.9) 240(356)
3 8 10 0.036(0.91) 0.060(1.52) 0.61(15.5) 305(453)
4 8 10 0.036(0.91) 0.060(1.52) 0.67(17.0) 380(561)
3 6 8 0.038(0.97) 0.060(1.52) 0.70(17.7) 440(652)
4 6 8 0.038(0.97) 0.060(1.52) 0.77(19.4) 550(812)
3 4 8 0.049(1.24) 0.060(1.52) 0.85(21.5) 640(952)
4 4 8 0.049(1.24) 0.080(2.03) 0.97(24.7) 850(1,260)
3 2 6 0.049(1.24) 0.080(2.03) 1.01(25.8) 980(1,455)
4 2 6 0.049(1.24) 0.080(2.03) 1.11(28.3) 1.235(1.836)
3 1 6 0.060(1.52) 0.080(2.03) 1.15(29.1) 1,210(1,800)
4 1 6 0.060(1.52) 0.080(2.03) 1.26(32.1) 1,540(2,286)
3 1/0 6 0.060(1.52) 0.080(2.03) 1.23(31.3) 1,450(2,154)
4 1/0 6 0.060(1.52) 0.080(2.03) 1.36(34.5) 1,850(2,750)
3 2/0 6 0.060(1.52) 0.080(2.03) 1.32(33.7) 1,745 (2,592)
4 2/0 6 0.060(1.52) 0.080(2.03) 1.46(37.2) 2,235(3,326)
3 3/0 4 0.060(1.52) 0.080(2.03) 1.44(36.5) 2,160(3,209)
4 3/0 4 0.060(1.52) 0.080(2.03) 1.59(40.3) 2,770(4,116)
3 4/0 4 0.060(1.52) 0.080(2.03) 1.56(39.5) 2,615(3,890)
4 4/0 4 0.060(1.52) 0.080(2.03) 1.72(43.7) 3,370(5,012)
3 250 4 0.071(1.80) 0.080(2.03) 1.71(43.4) 3,080(4581)
4 250 4 0.071(1.80) 0.110(2.79) 1.95(49.6) 4,090(6,083)
3 350 3 0.071(1.80) 0.110(2.79) 1.99(50.5) 4.265(6.340)
4 350 3 0.071(1.80) 0.110(2.79) 2.2(55.9) 5,505(8,186)
3 500 2 0.071(1.80) 0.110(2.79) 2.27(57.6) 5.850(8.701)
4 500 2 0.071(1.80) 0.110(2.79) 2.51(63.8) 7,580(11,276)
3 750 1 0.082(2.08) 0.110(2.79) 2.70(68.6) 8,535(12,700)
4 750 1 0.082(2.08) 0.140(3.56) 3.06(77.8) 11.295(16,807)
 
SÈTIFIKASYON

 

PVC Nylon Industrial Cable

Anbalaj

 

THHN THWN-2 Tray Cable
Gwo bobine an bwa
Direct Burial Tray Cable
Gwo bobine an bwa
APLIKASYON

 

Class I Div 2 Tray Cable
Plant endistriyèl
UL1277 Tray Cable
Etablisman Mining
600V Tray Cable
Plant pouvwa
KA

 

THHN THWN-2 Tray Cable

Sistèm depo enèji batri

600V THHN Tray Cable

Estasyon elektrik Bechatw

General Purpose Industrial Cable

Bingham Canyon min

POUKISA CHWAZI NOU

 

30Ane eksperyans
nan yon sèl-sèvis

Dongguan Greater Wire & Cable Co., Ltd. se yon manifakti kab pwofesyonèl jeni -nan Lachin, ki bay solisyon kab elektrik sètifye pou pwojè bilding, endistriyèl, min, enèji ak enfrastrikti atravè lemond.

Avèk yon faktori 30,000 m², 30 liy pwodiksyon, enjenyè ki gen eksperyans, ak yon ekip kontwòl kalite strik, nou bay pwodwi kab serye, trasabl, ak konfòme pou aplikasyon jeni entènasyonal yo. Pwodwi nou yo sipòte pa sètifikasyon ki gen ladan SAA, UL, cUL, VDE, TÜV, CE, CB, IEC, BPS, ak ISO.

Nou pran angajman pou sekirite, kalite, transparans, ak patenarya alontèm-. Soti nan enspeksyon matyè premyè rive nan tès pwodwi fini, chak pakèt yo ak anpil atansyon kontwole pou asire pèfòmans ki estab ak itilizasyon serye nan pwojè.

Pi gwo kab - Kalite sètifye. Pwovizyon pou serye. Valè Jeni.

Mining Power Cable
 
15K
Pwojè fini
150+
anplwaye pwofesyonèl
15K
kliyan kontan
92+
prim ak sètifika
EKIPMAN PLANT

 

Mining Electrical Cable
 
UL1277 Cable Standard
 
Tray Cable
 
Copper Stranded Tray Cable
 
Shielded Tray Cable
 
XLPE Insulated Tray Cable
 
SÈTIFIKASYON GLOBAL

 

4/0 Tray Cable

FOTO KLIYAN
 

Flame Retardant Cable

TRANSPÒ ENTERNASYONAL

 

01

Kago lanmè

Nou ofri solisyon machandiz fyab pou gwo -lòd volim. Machandiz ou yo byen chaje ak anbake nan resipyan, sa ki garanti pri -livrezon efikas nan pò atravè lemond.

02

Air machandiz

Pou livrezon pi rapid, sèvis machandiz lè nou an asire pwodwi ou yo rive nan destinasyon entènasyonal yo byen vit, ak manyen atansyon ak swiv konplè sou wout la.

03

Entènasyonal Express

Bezwen anbakman ijan? Sèvis entènasyonal eksprime nou an delivre ti kòmand mwayen avèk efikasite, bay sèvis pòt-a-pòt ak tan reyèl-swiv pou lapè lespri.

Renewable Energy Electrical Cable
PATÈ Koperativ

 

Nou ap chèche yon patnè koperativ pou elaji biznis nou an.

ESS Battery
Battery Energy Storage Cable
Exposed Run Cable
Sunlight Resistant Cable
FT4 Rated Cable
90°C Rated Cable
Low Smoke Cable
Process Plant Electrical Cable
Machine Tool Cable
TC-ER Cable for Oil and Gas
Kijan Pou Kowopere Ak Nou?

Senpleman pataje kondisyon ou yo, resevwa solisyon pwofesyonèl nou an, konfime echantiyon yo epi jwi pwodiksyon rapid, serye ak livrezon atravè lemond - travay avèk nou se sa ki fasil.

Adrès nou an

Bilding 2, No. 40 Luxi 2nd Road, Liaobu Town, Dongguan City, Guangdong Province, Lachin

Nimewo Telefòn

+86 136 6257 9592

+86 135 1078 4550

E-lapòs

manager01@greaterwire.com

TC-ER Cable Installation Method
FAQ

 

Ki tansyon maksimòm rale pou 4/0 AWG TC-ER?
4/0 AWG mande anpil tansyon rale. Sèvi ak ekipman rale apwopriye ak siveyans tansyon pou anpeche domaj nan kondiktè yo ak izolasyon.
Èske 4/0 AWG mande pou reyon koube espesyal pandan enstalasyon?
Wi, 4/0 AWG gen yon pi gwo reyon koube minimòm pase pi piti mezi. Konsilte fèy done manifakti a pou kondisyon espesifik reyon koube pou evite domaj izolasyon.
Ki kalite pakèt yo rekòmande pou revokasyon 4/0 AWG?
Yo rekòmande pattes konpresyon ak mouri apwopriye pou 4/0 AWG. Asire ke lug la rated pou kondiktè kwiv epi swiv espesifikasyon koupl manifakti a.
Èske kab sa a ka itilize pou kondwi motè VFD?
Wi, 4/0 AWG TC-ER apwopriye pou kondwi motè VFD. Izolasyon PVC + Nylon bay bon pwoteksyon kont pwent vòltaj ak estrès elektrik.

 

Hot Tags: 4/0 awg ul1277 tc-er plato kab ak thhn thwn-2 kondiktè, Lachin 4/0 awg ul1277 tc-er plato kab ak thhn thwn-2 kondiktè manifaktirè, founisè, faktori

Send Inquiry