12 AWG UL Kalite TC -ER Plato Kab XLPE PVC Kontwòl Kab

12 AWG UL Kalite TC -ER Plato Kab XLPE PVC Kontwòl Kab
Details:
·PVC an jeneral jakèt
· XLPE D'
·Blanke Bare Copper Kondiktè
· Ripcord (jan sa nesesè)
·20 AWG Tinned Copper Drenaj Fil
· Filler (jan sa nesesè)
· Evalyasyon vòltaj: 600V
· Tanperati: Evalyasyon nan 90 degre mouye oswa sèk
·Dimansyon gwosè: 14-10 AWG
· Estanda: UL44/UL1277
·Disponib nan 2 jiska 37 kondiktè
· Koulè: nwa
Send Inquiry
Download
Deskripsyon
Paramèt teknik
Sètifikasyon

 

sunlight resistant Type TC-ER control cable

PWODWI REAL SHOT

 

direct burial 600V control cable
wet dry rated 600V control cable
90C wet dry 600V control cable

flame retardant Type TC-ER control cable

12 AWG TC-ER – Kontra enfòmèl ant XLPE izolasyon plato kab pou kontwòl ak enstrimantasyon sikwi
Plato kab nan faktori modèn yo chaje ak fil elektrik, epi mete tout bagay nan espas limite mande pou seleksyon kab atansyon. Sa a12 AWG TC-ER kab kontwòlofri balans ideyal la nan kapasite aktyèl ak gwosè kontra enfòmèl ant pou kontwòl ak sikwi instrumentation. Konstwi ak izolasyon XLPE, kondiktè kwiv ki bloke, ak yon jakèt PVC dirab, li delivre pèfòmans serye nan plato kab ak enstalasyon kanal.UL1277 ak UL44 sètifye ak yon evalyasyon 600V, kab sa a se Kalite TC-ER nominale pou enstalasyon plato kouri ki ekspoze san kanal. Izolasyon XLPE a bay ekselan rezistans nan chalè, imidite, ak pwodwi chimik yo, sa ki fè li apwopriye pou automatisation faktori, panno kontwòl, ak sistèm Capteur. Gwosè a 12 AWG se ideyal pou20A sikwi kontwòlak ba-koneksyon ekipman pouvwa kote espas se yon prim men fyab yo pa ka konpwomèt.
PWODWI SPECIFICATIONS

 

low voltage 600V control cable

Deskripsyon Product

 

XLPE/PVC, 600V Kontwòl, Kalite TC-ER Câbles Antèman Dirèk yo konpoze de kondiktè ki kouvri nèt ak kòb kwiv mete nu Klas B, ki kouvri ak lwil oliv ak gaz rezistan Cross-Polyethylene lye (XLPE), ki pa pwoteje oswa ki pwoteje ak yon jakèt PVC nwa. Sa yo câbles yo te itilize nan pouvwa endistriyèl oswa sikui kontwòl estasyon.

Aplikasyon

 
  • Nan kanal, kanal, lè gratis, kous ak antèman dirèk, enstalasyon prensipal yo enkli plato kab, ak kote deyò.
  • Nan kote ki mouye oswa sèk
  • Apwouve pou Klas I, Div. 2 kote ki gen danje ladan pou chak NEC
  • Pèmèt pou Exposed Run (ER) itilize an akò ak NEC pou 3 oswa plis kondiktè; de kondiktè san yon fil tè se Kalite TC sèlman

Karakteristik

 
  • Evalyasyon nan 90 degre mouye oswa sèk
  • Rippor (jan sa nesesè)
  • Ekselan rezistans limyè solèy la
  • Satisfè tès koube frèt nan -25 degre
SPECIFICATIONS

Konte kondiktè

Disponib nan 2 jiska 37 kondiktè

Kondiktè

Klas B kòb kwiv mete totalman rkwit

Gwosè kalib

Disponib nan 14 jiska 10 AWG

Izolasyon

  • Polietilèn ki lye -kwaze (XLPE)
  • 14 AWG ak pi gwo yo se kalite XHHW-2
Koulè kodaj Dapre ICEA S-58-679 Metòd 1, Tablo E-2; opsyon adisyonèl kodaj koulè ki disponib
Ranpli File ki pa -igroskopik, jan sa nesesè pou jwenn yon kondiktè fini wonn
Shield (si ou vle) An jeneral papye polyester aliminyòm an kontak ak 20 AWG bloke fil fèblan drenaj kwiv
Jacket Klori polivinil (PVC)

Marking jakèt

Tape TC-ER (3 oswa plis kondiktè)
Gwosè kondiktè 14 AWG - 10 AWG: 00000 FT GREATER FIL XXAWG XX/C XHHW-2 PVC JKT (oswa OS) 600V 90C TIP MOYE OSWA SEK TC-ER (UL) SUN RES DIR BUR FE NAN CHINA MMDDYYY

Kalite TC (2 kondiktè)
Gwosè kondiktè 14 AWG - 10 AWG: 00000 FT GREATER FIL XXAWG XX/C XHHW-2 PVC JKT (oswa OS) 600V 90C TIP MOYE OSWA SEK TC (UL) SUN RES DIR BUR FE NAN CHINA MMDDYYYY

Anbalaj

Bobine bwa ki pa ka retounen -nan yon varyete longè ak dimansyon

Konfòmite pèfòmans

ASTM B3, ASTM B8, ASTM B33
UL 44
UL1277
UL 1685 (tès ekspoze flanm dife)
ANSI/NEMA WC 70/ICEA S-95-658
NEC

Lòt Konfòmite

EPA 40 CFR, Pati 261
OSHA
RoHS-konfòme/RoHS 2-konfòme
REACH-konfòme

San pwoteksyon

Konte kondiktè Gwosè kondiktè
AWG
Epesè izolasyon
nan (mm)
Epesè jakèt
nan (mm)
Apeprè. An jeneral dyamèt
nan (mm)
Apeprè. Pwa nèt
lbs/kft (kg/km)
2 14 0.030(0.76) 0.045(1.14) 0.37(9.3) 65(95)
3 14 0.030(0.76) 0.045(1.14) 0.39(9.9) 85(124)
4 14 0.030(0.76) 0.045(1.14) 0.42(10.8) 105(154)
5 14 0.030(0.76) 0.045(1.14) 0.46(11.7) 125(185)
7 14 0.030(0.76) 0.045(1.14) 0.50(12.7) 165(242)
9 14 0.030(0.76) 0.060(1.52) 0.62(15.8) 225(333)
12 14 0.030(0.76) 0.060(1.52) 0.69(17.5) 285(422)
19 14 0.030(0.76) 0.060(1.52) 0.80(20.4) 425(632)
25 14 0.030(0.76) 0.080(2.03) 0.98(24.9) 590(874)
30 14 0.030(0.76) 0.080(2.03) 1.04(26.3) 685(1,018)
37 14 0.030(0.76) 0.080(2.03) 1.11(28.3) 820(1,218)
2 12 0.030(0.76) 0.045(1.14) 0.40(10.2) 85(125)
3 12 0.030(0.76) 0.045(1.14) 0.43(10.8) 115(166)
4 12 0.030(0.76) 0.045(1.14) 0.47(11.8) 145(209)
5 12 0.030(0.76) 0.045(1.14) 0.51(12.9) 170(253)
7 12 0.030(0.76) 0.060(1.52) 0.59(14.9) 245(361)
9 12 0.030(0.76) 0.060(1.52) 0.69(17.4) 310(455)
12 12 0.030(0.76) 0.060(1.52) 0.76(19.4) 395(582)
19 12 0.030(0.76) 0.080(2.03) 0.93(23.7) 630(937)
25 12 0.030(0.76) 0.080(2.03) 1.09(27.6) 815(1,209)
30 12 0.030(0.76) 0.080(2.03) 1.15(29.2) 955(1,415)
37 12 0.030(0.76) 0.080(2.03) 1.24(31.4) 1,150(1,705)
2 10 0.030(0.76) 0.080(2.03) 0.45(11.4) 115(170)
3 10 0.030(0.76) 0.045(1.14) 0.48(12.1) 155(231)
4 10 0.030(0.76) 0.045(1.14) 0.52(13.3) 200(294)
5 10 0.030(0.76) 0.045(1.14) 0.60(15.4) 260(385)
7 10 0.030(0.76) 0.060(1.52) 0.66(16.7) 345(508)
9 10 0.030(0.76) 0.060(1.52) 0.77(19.6) 435(644)
12 10 0.030(0.76) 0.060(1.52) 0.86(21.8) 560(831)

an jeneral pwoteje

Konte kondiktè Gwosè kondiktè
AWG
Epesè izolasyon
nan (mm)
Epesè jakèt
nan (mm)
Apeprè. An jeneral dyamèt
nan (mm)
Apeprè. Pwa nèt
lbs/kft (kg/km)
2 14 0.030(0.76) 0.045(1.14) 0.37(9.4) 70(102)
3 14 0.030(0.76) 0.045(1.14) 0.39(10.0) 90(131)
4 14 0.030(0.76) 0.045(1.14) 0.43(10.8) 110(162)
5 14 0.030(0.76) 0.045(1.14) 0.46(11.8) 130(193)
7 14 0.030(0.76) 0.045(1.14) 0.50(12.8) 170(250)
9 14 0.030(0.76) 0.060(1.52) 0.62(15.9) 230(342)
12 14 0.030(0.76) 0.060(1.52) 0.69(17.6) 290(431)
19 14 0.030(0.76) 0.060(1.52) 0.81(20.5) 435(642)
25 14 0.030(0.76) 0.080(2.03) 0.98(25.0) 600(886)
30 14 0.030(0.76) 0.080(2.03) 1.04(26.4) 695(1029)
37 14 0.030(0.76) 0.080(2.03) 1.12(28.4) 830(1231)
2 12 0.030(0.76) 0.045(1.14) 0.41(10.3) 90(132)
3 12 0.030(0.76) 0.045(1.14) 0.43(10.9) 120(173)
4 12 0.030(0.76) 0.045(1.14) 0.47(11.9) 150(217)
5 12 0.030(0.76) 0.045(1.14) 0.51(13.0) 180(261)
7 12 0.030(0.76) 0.060(1.52) 0.59(15.0) 250(369)
9 12 0.030(0.76) 0.060(1.52) 0.69(17.5) 315(464)
12 12 0.030(0.76) 0.060(1.52) 0.76(19.4) 400(592)
19 12 0.030(0.76) 0.080(2.03) 0.94(23.8) 640(948)
25 12 0.030(0.76) 0.080(2.03) 1.09(27.7) 825(1221)
30 12 0.030(0.76) 0.080(2.03) 1.15(29.2) 960(1428)
37 12 0.030(0.76) 0.080(2.03) 1.24(31.5) 1155(1718)
2 10 0.030(0.76) 0.045(1.14) 0.45(11.5) 120(177)
3 10 0.030(0.76) 0.045(1.14) 0.48(12.2) 165(238)
4 10 0.030(0.76) 0.045(1.14) 0.53(13.4) 205(302)
5 10 0.030(0.76) 0.060(1.52) 0.61(15.4) 265(393)
7 10 0.030(0.76) 0.060(1.52) 0.66(16.8) 350(517)
9 10 0.030(0.76) 0.060(1.52) 0.78(19.7) 440(653)
12 10 0.030(0.76) 0.080(2.03) 0.90(23.0) 605(894)

 

SÈTIFIKASYON

 

indoor outdoor 600V control cable

Anbalaj

 

raceway installation Type TC-ER control cable

Woule

conduit installation XLPE PVC control cable

Bobine plastik

free air installation Type TC-ER control cable

Ti bobine an bwa

APLIKASYON

 

wet location Type TC-ER control cable
Otomatik faktori
dry location XLPE PVC control cable
Enstrimantasyon pwosesis
hazardous location XLPE PVC control cable
Sistèm Kontwòl Tretman Dlo
KA

 

Class II Div 2 600V control cable

BASF Ludwigshafen Verbund Site

Class III Div 2 600V control cable

MWRA Deer Island Wastewater Treatment Plant

messenger supported 600V control cable

Siemens Elektwonik Works Amberg faktori

POUKISA CHWAZI NOU

 

30Ane eksperyans
nan yon sèl-sèvis

Dongguan Greater Wire & Cable Co., Ltd. se yon manifakti kab pwofesyonèl jeni -nan Lachin, ki bay solisyon kab elektrik sètifye pou pwojè bilding, endistriyèl, min, enèji ak enfrastrikti atravè lemond.

Avèk yon faktori 30,000 m², 30 liy pwodiksyon, enjenyè ki gen eksperyans, ak yon ekip kontwòl kalite strik, nou bay pwodwi kab serye, trasabl, ak konfòme pou aplikasyon jeni entènasyonal yo. Pwodwi nou yo sipòte pa sètifikasyon ki gen ladan SAA, UL, cUL, VDE, TÜV, CE, CB, IEC, BPS, ak ISO.

Nou pran angajman pou sekirite, kalite, transparans, ak patenarya alontèm-. Soti nan enspeksyon matyè premyè rive nan tès pwodwi fini, chak pakèt yo ak anpil atansyon kontwole pou asire pèfòmans ki estab ak itilizasyon serye nan pwojè.

Pi gwo kab - Kalite sètifye. Pwovizyon pou serye. Valè Jeni.

UL 1277 600V control cable
 
15K
Pwojè fini
150+
anplwaye pwofesyonèl
15K
kliyan kontan
92+
prim ak sètifika
EKIPMAN PLANT

 

UL 44 Type TC-ER cable
 
UL 1685 control cable
 
UL 1685 600V control cable
 
IEEE 1202 control cable
 
IEEE 1202 600V control cable
 
UL 1581 control cable
 
SÈTIFIKASYON GLOBAL

 

VW-1 control cable

FOTO KLIYAN
 

TC ER control cable

TRANSPÒ ENTERNASYONAL

 

01

Kago lanmè

Nou ofri solisyon machandiz fyab pou gwo -lòd volim. Machandiz ou yo byen chaje ak anbake nan resipyan, sa ki garanti pri -livrezon efikas nan pò atravè lemond.

02

Air machandiz

Pou livrezon pi rapid, sèvis machandiz lè nou an asire pwodwi ou yo rive nan destinasyon entènasyonal yo byen vit, ak manyen atansyon ak swiv konplè sou wout la.

03

Entènasyonal Express

Bezwen anbakman ijan? Sèvis entènasyonal eksprime nou an delivre ti kòmand mwayen avèk efikasite, bay sèvis pòt-a-pòt ak tan reyèl-swiv pou lapè lespri.

direct burial control cable
PATÈ Koperativ

 

Nou ap chèche yon patnè koperativ pou elaji biznis nou an.

station control cable
class B stranded copper control cable
XLPE PVC cable supplier
600V multi conductor control cable
UL tray cable manufacturer
XLPE PVC tray control cable
600V control cable supplier
XLPE/PVC 600V control Type TC-ER cable
XLPE/PVC XHHW-2 600V control cable
stranded copper XLPE PVC control cable
Kijan Pou Kowopere Ak Nou?

Senpleman pataje kondisyon ou yo, resevwa solisyon pwofesyonèl nou an, konfime echantiyon yo epi jwi pwodiksyon rapid, serye ak livrezon atravè lemond - travay avèk nou se sa ki fasil.

Adrès nou an

Bilding 2, No. 40 Luxi 2nd Road, Liaobu Town, Dongguan City, Guangdong Province, Lachin

Nimewo Telefòn

+86 136 6257 9592

+86 135 1078 4550

E-lapòs

manager01@greaterwire.com

shielded XLPE PVC TC-ER control cable
FAQ

 

Ki aplikasyon tipik pou kab 12 AWG TC-ER sa a?
Aplikasyon tipik yo enkli sikui kontwòl, fil elektrik enstriman, koneksyon detèktè, ak ekipman ki ba -nan automatisation faktori ak plant endistriyèl.
Èske kab sa a apwopriye pou enstalasyon nan kanal osi byen ke plato kab?
Wi, kab sa a ka enstale nan tou de plato kab ak sistèm kanalizasyon, bay fleksibilite enstalasyon.
Ki sètifikasyon kab sa a pote?
Kab sa a sètifye dapre estanda UL1277 (Tray Cable) ak UL44 (Thermoset-Izolasyon Fil).
Èske kab sa a ka pote tou de siyal pouvwa ak kontwòl?
Wi, gwosè 12 AWG a apwopriye pou tou de siyal kontwòl ak sikui pouvwa ki ba -, men sikwi separe yo ta dwe separe nan plato a.

 

Hot Tags: 12 awg ul tip tc-er plato kab xlpe pvc kontwòl kab, Lachin 12 awg ul tip tc-er plato kab xlpe pvc kontwòl kab manifaktirè, founisè, faktori