15kV Mwayen Voltage Kab CU EPR Copper Tap Shield PVC Tip MV-105 133% IL. 220 Mils Shielded Power Cable

15kV Mwayen Voltage Kab CU EPR Copper Tap Shield PVC Tip MV-105 133% IL. 220 Mils Shielded Power Cable
Details:
· Kondiktè kwiv bloke (pa ranpli/plen)
·Extruded Strand Shield
·Izolasyon: EPR
·Extruded izolasyon plak pwotèj
· Kouvèti kasèt kwiv
·PVC an jeneral jakèt
· Evalyasyon vòltaj: 5KV-35KV
· Tanperati: 105 degre
· Ranje gwosè: 2AWG ~ 1000kcmil
· Estanda: UL1072
·Nwayo sèl
· Koulè: nwa
Send Inquiry
Download
Deskripsyon
Paramèt teknik
Sètifikasyon

single conductor type mv-105 cable

PWODWI REAL SHOT

 

single conductor mv-105 cable
copper conductor type mv-105 cable
single core copper mv-105 cable

type mv-105 copper cable

15kV 133% Nivo izolasyon - 220 mils Copper Tape pwoteje MV-105 Kab pou pwojè poste
Nousèl kondiktè kwiv tip MV-105 kabse UL 1072 & NEC Atik 328 sètifye. Li adopte kondiktè kwiv solid, izolasyon EPR ak133% nivo izolasyon, kasèt kwiv plak pwotèj metalik ak PVC ekstèn jakèt. Rated 105 degre tanperati kontinyèl, sa a sèl nwayo kwiv MV-105 kab lajman ki itilize nan 15kV anba tè kanal bank, poste ak endistriyèl mwayen vòltaj feeder pwojè.
PWODWI SPECIFICATIONS

 

single conductor medium voltage cable copper

DESKRIPSYON PWODWI

 

Vòltaj Mwayen, EPR/Cu Tape Shield/PVC, Kalite MV-105 Kab konpoze de kondiktè ki kouvri nèt ak kwiv klas B ki kouvri, ki kouvri ak kawoutchou etilèn pwopilèn (EPR), plak pwotèj kasèt kwiv, ak jakèt PVC nwa. Sa yo câbles yo te itilize nan sikui pouvwa endistriyèl.

APLIKASYON

 

·  Nan kanal, kanal, lè gratis, ak kous, enstalasyon prensipal yo enkli plato kab, ak kote deyò

· Nan antèman dirèk si enstale nan yon sistèm ki gen yon kondiktè tè ki toupre, epi ki konfòm ak NEC 250.4 (A) (5)

· Nan kote ki mouye oswa sèk

· Apwouve pou Klas I, Div. 2 kote ki gen danje ladan pou chak NEC

· Ki fèt pou opere kontinyèlman nan yon tanperati kondiktè ki pa depase

eksprime 105 degre pou operasyon nòmal

eksprime 140 degre pou surcharge ijans

eksprime 250 degre pou sikwi kout

Karakteristik

 

·  Evalyasyon nan 105 degre mouye oswa sèk· Ba pèt dyelèktrik
·  Ekselan rezistans corona·  Ekselan rezistans limyè solèy la
·  Segondè fòs dyelèktrik·  Pou CT USE pou 1/0 AWG ak pi gwo, pou chak UL® 1072                      
·  Absòpsyon imidite ki ba·  Satisfè tès koube frèt nan -35 degre

SPECIFICATIONS

Konte kondiktè

1 kondiktè

Kondiktè

Konplètman rkwit kòb kwiv mete vid Klas B konprese fil (plen oswa non)

Gwosè kalib

Disponib nan 2 AWG jiska 1000 kcmil

Kondiktè Strand Shield

Ekstrude thermoset semi-polymère kondiktè sou kondiktè a

Izolasyon

Kawotchou etilèn pwopilèn (EPR)

Izolasyon Shield

Ekstrude tèrmoset semi-polymère konduit sou izolasyon an

Shield

5 mil tep an kwiv recuit helically aplike ak apeprè 25% sipèpoze

Jacket

Klori polivinil (PVC)

Marking jakèt

2 AWG - 1 AWG:00000 FT GREATER FIL KABLE XXAWG 1/C XXXV XXX% NIVO INSUL XXXMILS EPR/PVC JKT TIP MV-105 SUN RES (UL) FÈ OZE-ZINI MMDDYYYY (LIGHTNING BOLT)
1/0 AWG - 1000 kcmil:00000 FT GREATER FIL KABLE XXAWG (oswa XXXKCMIL) 1/C XXXV XXX% NIVO IZIL XXXMILS EPR/PVC JKT TIP MV-105 POU ITILIZE CT (UL) SOLÈY RES TE FE OZEtazini MMDDYYYY (LIGHTNING BOLT)

Anbalaj

Bobine bwa ki pa ka retounen -nan yon varyete longè ak dimansyon

Konfòmite pèfòmans

ASTM B3|ASTM B8
UL 1072, UL 1685 (tès ekspoze flanm dife)
ANSI/NEMA WC 74/ICEA S-93-639
ANSI/ICEA S-97-682
AEIC CS8
NEC

Lòt Konfòmite

EPA 40 CFR, Pati 261
OSHA

Copper Unfilled/Filled Cdr 5kV 100% IL. 90 mils, pwoteje

Kondiktè
Gwosè

Nom.Conductor
Dyamèt

Izolasyon
Dyamèt2
Epesè jakèt2 Apeprè. An jeneral dyamèt2 Apeprè. Pwa nèt2 Anpasite
AWG/Kcmil nan (mm) nan (mm) nan (mm) nan (mm) lbs/kft (kg/km) Konduit nan lè3

Uanba tè

Kannal4

2 0.283(7.2) 0.78(19.8) 0.075 (1.9) 1.02 (25.9) 645(960) 165 165
1 0.322(8.2) 0.82(20.8) 0.075 (1.9) 1.06 (26.9) 725(1,079) 185 185
1/0 0.362(9.2) 0.86(21.8) 0.075 (1.9) 1.10 (27.9) 815(1,213) 215 215
2/0 0.405(10.3) 0.90(22.9) 0.075 (1.9) 1.14 (29.0) 930(1,384) 245 245
3/0 0.456 (11.6) 0.96(24.4) 0.075 (1.9) 1.20 (30.5) 1,070(1,592) 280 275
4/0 0.512(13.0) 1.01(25.7) 0.075 (1.9) 1.25 (31.8) 1,235(1,838) 320 315
250 0.558(14.2) 1.07(27.2) 0.075 (1.9) 1.31 (33.3) 1,395(2,076) 350 345
350 0.661(16.8) 1.17(29.7) 0.075 (1.9) 1.42 (36.1) 1,765(2,626) 430 415
500 0.789(20.0) 1.30(33.0) 0.075 (1.9) 1.55 (39.4) 2,305(3,430) 525 500
750 0.968(24.6) 1.50(38.1) 0.075 (1.9) 1.74 (44.2) 3,190(4,747) 635 610
1000 1.117(28.4) 1.65(41.9) 0.105 (2.7) 1.96 (49.8) 4,165(6,197) 725 690
 
SÈTIFIKASYON

 

single core shielded medium voltage cable copper

Anbalaj

 

1C aluminum Type MV-105 cable
Gwo bobine an bwa
Al conductor MV-105 cable
Gwo bobine an bwa
APLIKASYON

 

medium voltage mv-105 cable copper
Plant endistriyèl
single conductor shielded power cable copper
Etablisman Mining
single conductor copper medium voltage power cable
Plant pouvwa
KA

 

single conductor 105c medium voltage cable copper

Sistèm depo enèji batri

mv-105 type mv cable copper conductor

Estasyon elektrik Bełchatów

single conductor copper type mv cable

Bingham Canyon min

POUKISA CHWAZI NOU

 

30Ane eksperyans
nan yon sèl-sèvis

Dongguan Greater Wire & Cable Co., Ltd. se yon manifakti kab pwofesyonèl jeni -nan Lachin, ki bay solisyon kab elektrik sètifye pou pwojè bilding, endistriyèl, min, enèji ak enfrastrikti atravè lemond.

Avèk yon faktori 30,000 m², 30 liy pwodiksyon, enjenyè ki gen eksperyans, ak yon ekip kontwòl kalite strik, nou bay pwodwi kab serye, trasabl, ak konfòme pou aplikasyon jeni entènasyonal yo. Pwodwi nou yo sipòte pa sètifikasyon ki gen ladan SAA, UL, cUL, VDE, TÜV, CE, CB, IEC, BPS, ak ISO.

Nou pran angajman pou sekirite, kalite, transparans, ak patenarya alontèm-. Soti nan enspeksyon matyè premyè rive nan tès pwodwi fini, chak pakèt yo ak anpil atansyon kontwole pou asire pèfòmans ki estab ak itilizasyon serye nan pwojè.

Pi gwo kab - Kalite sètifye. Pwovizyon pou serye. Valè Jeni.

copper conductor mv power cable 105c
 
15K
Pwojè fini
150+
anplwaye pwofesyonèl
15K
kliyan kontan
92+
prim ak sètifika
EKIPMAN PLANT

 

5kv copper conductor type mv-105 cable
 
5kv shielded copper mv-105 cable
 
5kv copper tape shield mv-105 cable single conductor
 
5kv epr insulated copper mv-105 cable single conductor
 
5kv ul 1072 mv-105 cable copper conductor
 
8kv mv-105 medium voltage cable copper conductor
 
SÈTIFIKASYON GLOBAL

 

15kv mv-105 medium voltage cable copper conductor

FOTO KLIYAN
 

15kv epr insulated copper mv-105 cable single conductor

TRANSPÒ ENTERNASYONAL

 

01

Kago lanmè

Nou ofri solisyon machandiz fyab pou gwo -lòd volim. Machandiz ou yo byen chaje ak anbake nan resipyan, sa ki garanti pri -livrezon efikas nan pò atravè lemond.

02

Air machandiz

Pou livrezon pi rapid, sèvis machandiz lè nou an asire pwodwi ou yo rive nan destinasyon entènasyonal yo byen vit, ak manyen atansyon ak swiv konplè sou wout la.

03

Entènasyonal Express

Bezwen anbakman ijan? Sèvis entènasyonal eksprime nou an delivre ti kòmand mwayen avèk efikasite, bay sèvis pòt-a-pòt ak tan reyèl-swiv pou lapè lespri.

25kv copper conductor type mv-105 cable
PATÈ Koperativ

 

Nou ap chèche yon patnè koperativ pou elaji biznis nou an.

icea s-93-639 shielded copper mv-105 cable
nema wc 74 single core copper medium voltage cable
35kv copper tape shield mv-105 cable single conductor
ul 1072 15kv copper mv-105 cable
nec article 328 type mv-105 cable specification
icea s-93-639 copper conductor type mv cable 105c
nema wc 74 type mv-105 cable specification
35kv epr insulated copper mv-105 cable single conductor
ul 1072 single core copper medium voltage cable
icea s-93-639 copper conductor mv-105 cable
Kijan Pou Kowopere Ak Nou?

Senpleman pataje kondisyon ou yo, resevwa solisyon pwofesyonèl nou an, konfime echantiyon yo epi jwi pwodiksyon rapid, serye ak livrezon atravè lemond - travay avèk nou se sa ki fasil.

Adrès nou an

Bilding 2, No. 40 Luxi 2nd Road, Liaobu Town, Dongguan City, Guangdong Province, Lachin

Nimewo Telefòn

+86 136 6257 9592

+86 135 1078 4550

E-lapòs

manager01@greaterwire.com

aeic cs8 copper conductor type mv cable 105c
FAQ

 

Ki diferans ki genyen ant plak pwotèj kasèt kwiv ak plak pwotèj fil kwiv pou kab MV-105?
Kouvèti kasèt kwiv bay pwoteksyon sikonferans konplè pou limite egzeyat pasyèl, ki se chwa estanda pou sèl kondiktè MV-105 kab pouvwa.
Èske mwen ka chwazi izolasyon EPR oswa XLPE pou kondiktè sèl sa aMV-105 kab?
Wi. Nou pwodui izolasyon EPR ak TR-XLPE. EPR gen pi bon rezistans dlo-pye bwa pou enstalasyon antèman mouye dirèk.
Ki evalyasyon tanperati kab tip MV-105 genyen?
MV-105 se rated 105 degre maksimòm tanperati opere kontinyèl pou fil elektrik fèmen ak anba tè.
Ki aplikasyon komen pou kòb kwiv mete sèl nwayo MV-105 kab?
Sitou pou poste elektrik yo, plant endistriyèl yo, sant done, distribisyon sèvis piblik, enèji renouvlab ak sikui elektrik mwayen vòltaj bilding komèsyal yo.

 

Hot Tags: 15kV Mwayen Voltage Kab CU EPR Copper Tape Shield PVC Kalite MV-105 133% IL{. 220 Mils Shielded Power Cable, Lachin 15kV Mwayen Voltage Kab CU EPR Copper Tape Shield PVC Type MV-105 133% IL{. 220 Mils Shielded Power Cable manifaktirè, Swèd, faktori

Send Inquiry