Details:
·Kondiktè:RE: Klas 1 kondiktè kwiv solid RM: Klas 2 bloke sikilè oswa sikilè compacted SM: Klas 2 bloke sektè ki gen fòm
·Izolasyon: XLPE (Polyetilèn ki lye kwa -)
·Lenn pou kabann: PVC (klori polyvinyl)
· Djenn: PVC (klori polyvinyl)
·Evalyasyon vòltaj Uo/U: 0.6/1kV
·Evalyasyon Tanperati:Pandan enstalasyon -5 degre a +50 degre Enstalasyon fiks: -20 degre a +90 degre
· Estanda: IEC 60502-1, Gen pou VDE 0276-603, IEC/EN 60228 ignifuge flanm dife selon IEC/EN 60332-1-2
Send Inquiry
Download
Deskripsyon
Paramèt teknik
Sètifikasyon

 

N2XY-O 0.6/1kV distributor Austria

PWODWI REAL SHOT

 

buy N2XY-O 0.6/1kV Austria
N2XY-O 0.6/1kV datasheet Austria
N2XY-O 0.6/1kV catalogue Austria

N2XY-O 0.6/1kV CPR Austria

Kab enèji renouvlab ki estab 25mm² AC-bò pou enfrastrikti solè ak BESS
Plant solè yo, sit depo batri yo ak mikwogri yo bezwen kab vòltaj ki ba - sou bò AC ant varyateur ak tablo distribisyon. La25mm2 solè AC pouvwa kabsèvi ak kondiktè kwiv bloke, izolasyon XLPE ak yon djenn PVC pou routage fiks 0.6/1kV; li pa prezante kòm yon ranplasan pou kab kòd PV dedye. Gwosè sa a ka sipòte pi long oswa pi wo -chaj manje pase seksyon ki pi piti lè kalkil yo pèmèt, ak anpasite final la ak gout vòltaj tcheke kont enstalasyon an. GERITEL WIRE ka bay pwojè-dispozisyon debaz espesifik, longè tanbou, make ak dosye enspeksyon. Ekip akizisyon yo ka idantifye li tou kòm yon depo batri AC feeder kab oswa IEC 60502-1 25mm2 kab.
PWODWI SPECIFICATIONS

 

N2XY-O 0.6/1kV CPR Austria

Aplikasyon

 

Sa yo pouvwa ak kab fil elektrik fiks yo itilize pou ekipman pou elektrisite nan sistèm enstalasyon vòltaj ki ba. Yo byen adapte ak itilizasyon anba tè nan aplikasyon endistriyèl ak yon pwoteksyon mekanik adisyonèl. Kab sa yo ka fiks sou plato kab, nan kanal oswa fiks sou mi yo.

SPECIFICATIONS
Evalyasyon vòltaj Uo/U 0.6/1kV
Evalyasyon Tanperati

Pandan enstalasyon -5 degre a +50 degre

Enstalasyon fiks: -20 degre a +90 degre

Reyon koube minimòm Fiks: 12 x dyamèt jeneral
Kondiktè

RE: Klas 1 kondiktè kwiv solid

RM: Klas 2 bloke sikilè oswa sikilè konpakte

SM: Klas 2 bloke sektè ki gen fòm

Izolasyon XLPE (Polyetilèn ki lye kwa{0})
kabann PVC (klori polivinil)
Djenn PVC (klori polivinil)
Idantifikasyon Nwayo

3 nwayo: vèt / jòn, ble, mawon4 nwayo

4 nwayo: vèt / jòn, mawon, nwa, gri

5 nwayo: vèt / jòn, ble, mawon, nwa, gri

7 nwayo ak pi wo a: nwayo nwa ak, nimewo blan

Koulè djenn Nwa
ESTANDA IEC 60502-1, Gen pou VDE 0276-603, IEC/EN 60228 Ignifuge flanm dife selon IEC/EN 60332-1-2

DIMANSYON

NON. OF
NOU

NOMINALCROSS

ZONE SEKTIONAL

mm²

KONDIKTÈ

TIP

NOMINAL

Epesè

DE Izolasyon

mm

NOMINAL

Epesè

DE GANE

mm²

NOMINAL AN jeneral

DYAMET

mm

PWA NOMINAL

kg/km

1 16 RM 0.7 1.8 9.8 216
1 25 RM 0.9 1.8 11.5 318
1 35 RM 0.9 1.8 12.6 415
1 50 RM 1 1.8 14.1 543
1 70 RM 1.1 1.8 15.6 746
1 95 RM 1.1 1.8 17.6 1000
1 120 RM 1.2 1.8 19.2 1239
1 150 RM 1.4 1.8 21.2 1515
1 185 RM 1.6 1.8 23.1 1872
1 240 RM 1.7 1.8 25.8 2403
1 300 RM 1.8 1.8 2.78 2974
1 400 RM 2 1.9 31.1 3834
1 500 RM 2.2 2 34.9 4892
1 630 RM 2.8 2.8 46.6 6544
2 1.5 RE 0.7 1.8 10.1 145
2 2.5 RE 0.7 1.8 10.9 179
2 4 RE 0.7 1.8 11.8 226
2 6 RE 0.7 1.8 12.8 284
2 6 RM 0.7 1.8 13.1 295
2 10 RM 0.7 1.8 15 416
2 16 RM 0.7 1.8 17 581
2 25 RM 0.9 1.8 20.4 859
2 35 RM 0.9 1.8 22.5 1109
3 1.5 RE 0.7 1.8 10.5 162
3 2.5 RE 0.7 1.8 11.4 205
3 4 RE 0.7 1.8 12.4 265
3 6 RE 0.7 1.8 13.4 338
3 10 RM 0.7 1.8 15.8 505
3 16 RM 0.7 1.8 18 719
3 25 RM 0.9 1.8 21.6 1072
3 35 RM 0.9 1.8 23.9 1403
3 50 SM 1 1.9 23.8 1581
3 16/10 SM 0.7 1.8 19.8 875.5
3 25/16 SM 0.9/0.7 1.8 22.4 1223
3 35/16 SM 0.9/0.7 1.8 24.3 1557
3 50/25 SM 1/0.9 1.9 26.9 1863
3 70/35 SM 1.1/0.9 2 30 2594
3 95/50 SM 1.1/1 2.2 33.8 3505
3 120/70 SM 1.2/1.1 2.3 37 4440
3 150/70 SM 1.4/1.1 2.4 41.6 5333
3 185/95 SM 1.6/1.1 2.6 45.8 6701
3 240/120 SM 1.7/1.2 2.8 51.6 8674
3 300/150 SM 1.8/1.4 3 67.2 10624
4 1.5 RE 0.7 1.8 11.3 188
4 2.5 RE 0.7 1.8 12.2 240
4 4 RE 0.7 1.8 13.3 314
4 6 RE 0.7 1.8 14.5 408
4 10 RE 0.7 1.8 17.1 615
4 16 RE 0.7 1.8 19.6 885
4 25 RE 0.9 1.8 23.7 1330
4 35 RE 0.9 1.8 26.2 1758
4 50 SM 1 2 27.1 2082
4 70 SM 1.1 2.1 31.4 2937
4 95 SM 1.1 2.2 35 3955
4 120 SM 1.2 2.4 39.3 4979
4 150 SM 1.4 2.6 43.6 6129
4 185 SM 1.6 2.7 48 7591
4 240 SM 1.7 2.9 53.9 9875
4 300 SM 1.8 2.6 68.9 15124
5 1.5 RE 0.7 1.8 12.1 218
5 2.5 RE 0.7 1.8 13.1 281
5 4 RE 0.7 1.8 14.3 372
5 6 RE 0.7 1.8 15.6 486
5 10 RM 0.7 1.8 18.6 740
5 16 RM 0.7 1.8 21.3 1071
5 25 RM 0.9 1.8 25.9 1619
5 35 RM 0.9 1.8 28.8 2138
5 50 RM 1 2.1 29.4 2578
5 70 RM 1.1 2.2 33.7 3616
5 95 RM 1.1 2.4 38.6 4933
5 120 RM 1.2 2.5 42.6 6153
5 150 RM 1.4 2.7 47.7 7587
5 185 RM 1.6 2.9 52.8 9454
5 240 RM 1.7 3.1 58.7 12242
7 1.5 RE 0.7 1.8 12.9 260
7 2.5 RE 0.7 1.8 14 342
7 4 RE 0.7 1.8 15.4 461
10 1.5 RE 0.7 1.8 15.6 357
10 2.5 RE 0.7 1.8 17.2 475
10 4 RE 0.7 1.8 19 646
12 1.5 RE 0.7 1.8 16.1 394
12 2.5 RE 0.7 1.8 17.6 528
14 1.5 RE 0.7 1.8 16.8 436
14 2.5 RE 0.7 1.8 18.5 592
16 4 RM 0.7 1.8 23 971
19 1.5 RE 0.7 1.8 18.4 543
19 2.5 RE 0.7 1.8 20.3 746
24 1.5 RE 0.7 1.8 21.2 675
24 2.5 RE 0.7 1.8 23.4 931
30 1.5 RE 0.7 1.8 22.3 788
30 2.5 RM 0.7 1.8 26.3 7764
40 1.5 RE 0.7 1.8 24.6 995
40 2.5 RE 0.7 1.9 27.5 1416

KONDIKTÈ

Klas 1 kondiktè solid pou yon sèl-nwayo ak milti-nwayo kab

KWA NOMINAL

ZÒN EKTIONAL

mm²

REZISTANS MAXIMUM CONDUCTOR A 20 degre

ohm/km

Sikilè, rkwit kondiktè kwiv
Plain
0.5 36
0.75 24.5
1 18.1
1.5 12.1
2.5 7.41
4 4.61
6 3.08

 

Klas 2 kondiktè bloke pou yon sèl-nwayo ak milti-nwayo kab

KWA NOMINAL

SEKSYONAL ZÒN

mm²

MINIMÒM NO. DE FIL NAN CONDUCTOR A

REZISTANS MAXIMUM CONDUCTOR A 20 degre

ohm/km

Sikilè Sikilè Compact Kondiktè kwiv rkwit
Cu Cu Fil Plain
4 7 6 4.51
6 7 6 3.08
10 7 6 1.83
16 7 6 1.15
25 7 6 0.727
35 7 6 0.524
50 19 6 0.387
70 19 12 0.268
95 19 15 0.193
120 37 18 0.153
150 37 18 0.124
185 37 30 0.0991
240 37 34 0.0754
300 61 34 0.0601
400 61 53 0.0470
500 61 53 0.0366

Karakteristik elektrik

Kapasite aktyèl pote nan 30 degre

KWA NOMINAL

SZÒN EKTIONAL

mm²

SINGLE CORE

2-40 NOU

Ampè

Nan Tè Nan lè Nan Tè Nan lè
Flat Trefoil Flat Trefoil
1.5 - - - - 31 24
2.5 - - - - 40 32
4 82 54 57 44 52 42
6 102 67 72 56 64 53
10 136 89 99 77 86 74
16 176 115 131 102 112 98
25 229 148 177 138 145 133
35 275 177 217 170 174 162
50 326 209 265 207 206 197
70 400 256 336 263 254 250
95 480 307 415 325 305 308
120 548 349 485 380 348 359
150 616 393 557 437 392 412
185 698 445 646 507 444 475
240 815 517 774 604 517 564
300 927 663 901 697 585 649
400 1064 749 1060 811 - -
500 1227 843 1252 940 - -

DE-FAKTÈ KOTE

Pou Tanperati tè ki pa 20 degre

TANPERATI AIR 10degreC 15 degre 20 degre 25 degre 30 degre 35 degre 40 degre 45 degre 50 degre
DE-FAKTÈ RATING 1.07 1.04 1.00 0.96 0.93 0.89 0.85 0.80 0.76

 

Pou Tanperati lè ki pa 30 degre

TANPERATI AIR 20 degre 25 degre 30 degre 35 degre 40 degre 45 degre 50 degre 55 degre 60 degre
DE-FAKTÈ RATING 1.08 1.04 1.00 0.96 0.91 0.87 0.82 0.76 0.71
SÈTIFIKASYON

 

N2XY-O 0.6/1kV current rating Austria

Anbalaj

 

N2XY cable Switzerland

Woule

N2XY cable supplier Switzerland

Ti bobine an bwa

N2XY cable manufacturer Switzerland

Steel an bwa bobine

APLIKASYON

 

N2XY cable price Switzerland
Gwo -Komèsyal Komèsyal Distribisyon Pouvwa Prensipal
N2XY cable distributor Switzerland
Plant Endistriyèl Low -Voltage Power Distribution
buy N2XY cable Switzerland

Tretman Dlo Minisipal ak Ponpe Estasyon Power Supply

 

KA

 

N2XY cable datasheet Switzerland

Pwojè Transmisyon pouvwa Babanusa–Adila

N2XY cable catalogue Switzerland

Pwojè tès elektrisite Itali

N2XY cable CPR Switzerland

Oyu Tolgoi Copper Mine Project

POUKISA CHWAZI NOU

 

30Ane eksperyans
nan yon sèl-sèvis

Dongguan Greater Wire & Cable Co., Ltd. se yon manifakti kab pwofesyonèl jeni -nan Lachin, ki bay solisyon kab elektrik sètifye pou pwojè bilding, endistriyèl, min, enèji ak enfrastrikti atravè lemond.

Avèk yon faktori 30,000 m², 30 liy pwodiksyon, enjenyè ki gen eksperyans, ak yon ekip kontwòl kalite strik, nou bay pwodwi kab serye, trasabl, ak konfòme pou aplikasyon jeni entènasyonal yo. Pwodwi nou yo sipòte pa sètifikasyon ki gen ladan SAA, UL, cUL, VDE, TÜV, CE, CB, IEC, BPS, ak ISO.

Nou pran angajman pou sekirite, kalite, transparans, ak patenarya alontèm-. Soti nan enspeksyon matyè premyè rive nan tès pwodwi fini, chak pakèt yo ak anpil atansyon kontwole pou asire pèfòmans ki estab ak itilizasyon serye nan pwojè.

Pi gwo kab - Kalite sètifye. Pwovizyon pou serye. Valè Jeni.

N2XY cable current rating Switzerland
 
15K
Pwojè fini
150+
anplwaye pwofesyonèl
15K
kliyan kontan
92+
prim ak sètifika
EKIPMAN PLANT

 

Cu XLPE PVC cable Switzerland
 
YMvK 0.6/1 kV
 
Cu XLPE PVC cable supplier Switzerland
 
YMvK copper XLPE PVC cable
 
Cu XLPE PVC cable manufacturer Switzerland
 
Cu XLPE PVC cable price Switzerland
 
SÈTIFIKASYON GLOBAL

 

Cu XLPE PVC cable distributor Switzerland

FOTO KLIYAN
 

buy Cu XLPE PVC cable Switzerland

TRANSPÒ ENTERNASYONAL

 

01

Kago lanmè

Nou ofri solisyon machandiz fyab pou gwo -lòd volim. Machandiz ou yo byen chaje ak anbake nan resipyan, sa ki garanti pri -livrezon efikas nan pò atravè lemond.

02

Air machandiz

Pou livrezon pi rapid, sèvis machandiz lè nou an asire pwodwi ou yo rive nan destinasyon entènasyonal yo byen vit, ak manyen atansyon ak swiv konplè sou wout la.

03

Entènasyonal Express

Bezwen anbakman ijan? Sèvis entènasyonal eksprime nou an delivre ti kòmand mwayen avèk efikasite, bay sèvis pòt-a-pòt ak tan reyèl-swiv pou lapè lespri.

Cu XLPE PVC cable datasheet Switzerland
PATÈ Koperativ

 

Nou ap chèche yon patnè koperativ pou elaji biznis nou an.

Cu XLPE PVC cable catalogue Switzerland
Cu XLPE PVC cable CPR Switzerland
Cu XLPE PVC cable current rating Switzerland
U-1000 R2V France
U-1000 R2V supplier France
kabel miedziany XLPE PVC
U-1000 R2V manufacturer France
U-1000 R2V price France
U-1000 R2V distributor France
YKXS producent
Kijan Pou Kowopere Ak Nou?

Senpleman pataje kondisyon ou yo, resevwa solisyon pwofesyonèl nou an, konfime echantiyon yo epi jwi pwodiksyon rapid, serye ak livrezon atravè lemond - travay avèk nou se sa ki fasil.

Adrès nou an

Bilding 2, No. 40 Luxi 2nd Road, Liaobu Town, Dongguan City, Guangdong Province, Lachin

Nimewo Telefòn

+86 136 6257 9592

+86 135 1078 4550

E-lapòs

manager01@greaterwire.com

buy U-1000 R2V France
FAQ

 

Èske ou ka bay yon desen kwa-kab oswa yon fèy dimansyon?
Pou desen konstriksyon kab PVC Cu XLPE: Yon desen konstriksyon ka montre kondiktè, izolasyon, mete -nan nwayo, file ak djenn ak dimansyon nominal. Pwoblèm final la ta dwe matche ak konsepsyon pwodiksyon apwouve a. GERITEL WIRE ka kowòdone enspeksyon yon twazyèm pati lè yo dakò ak kad ak tan nan lòd acha a. Yon BOQ konplè ede anpeche konparezon pri ant konstriksyon kab materyèl diferan.
Ki jan ou kenbe lòd repete ki konsistan avèk premye pakèt la?
Sèvi ak yon spesifikasyon apwouve, bòdwo materyèl, prèv make, plan tès ak dosye pwodiksyon konsève. Nenpòt chanjman materyèl oswa konsepsyon ta dwe kominike anvan fabrikasyon. Yon serye lòd repete kab bon kalite konsistans desizyon Se poutèt sa bezwen yon baz konstriksyon ak enstalasyon apwouve. GERITEL WIRE sipòte lòd pwojè melanje-gwosè ak kab-revizyon orè ak alokasyon tanbou ekspòtasyon pratik. Enstalasyon ak revokasyon detay yo ta dwe tcheke pa enjenyè pwojè responsab la.
Ki tès woutin ki fèt sou chak longè kab fabrike?
Pwogram tès woutin la defini pa estanda ak konstriksyon ki aplikab yo e li anjeneral gen ladan chèk elektrik sou longè fabrike yo. Lòd la ta dwe endike ki dosye tès woutin yo dwe bay. Pou achtè kap chèche tès woutin IEC 60502-1 kab, GERITEL WIRE ka bay yon prèv make, desen konstriksyon ak pwopozisyon anbalaj komèsyal pou apwobasyon. Voye destinasyon an, estanda, gwosè, aranjman debaz, kantite ak wout enstalasyon pou yon òf egzak.
Èske ou ka bay yon rapò tès rezistans kondiktè?
Lè kliyan mande sou kwivrapò tès rezistans kondiktè, repons pratik la se: Wi, rezilta rezistans yo ka anrejistre pou pakèt pwodiksyon an epi konpare ak estanda kondiktè a apre koreksyon tanperati a. Egzanp idantifikasyon ta dwe lyen rapò a ak tanbou yo anbake. GERITEL WIRE ede achtè EPC fèmen twou vid ki genyen teknik yo anvan pwodiksyon pou ranplasman sit yo redwi. Pou sipò seleksyon, bay vòltaj sistèm, chaj, longè wout, metòd enstalasyon ak dokiman obligatwa yo.

 

Hot Tags: renouvlab -enèji AC feeder: 25mm2 iec 60502-1 kòb kwiv mete, Lachin renouvlab-enèji AC feeder: 25mm2 iec 60502-1 kwiv kab manifaktirè, Swèd, faktori

Send Inquiry